The Viscotek TDAmax is a complete, research grade, temperature controlled, multi-detector GPC/SEC system suitable for the molecular weight and molecular size determination of proteins, natural and synthetic polymers, copolymers and other macromolecules.

Overview

The TDAmax consists of three components – the GPCmax integrated solvent and sample delivery module, the Triple or Tetra Detector Array (TDA), incorporating RI, Light Scattering, Viscosity, optional UV detectors, and OmniSEC software. The integrated detectors and columns are fully temperature controlled up to 80°C to ensure optimum detector stability, and the detectors being series ensure maximum sensitivity.

  • Absolute molecular weight of small polymers, protein stability and protein aggregation using Right angle light scattering (RALS)
  • Direct output of absolute molecular weight of polymers without extrapolation using Low angle light scattering (LALS)
  • Protein and polymer structure information using intrinsic viscosity detector for all sample and solvent types
  • Molecular size in terms of hydrodynamic diameter and Rg
  • Copolymer composition using single or multi-wavelength UV detector
  • Autosampler incorporated to increase throughput and improve repeatability
  • Comprehensive functionality software featuring “two clicks from data to results’
  • 3D absorption plot for chemical identification of each component
  • 21 CFR part 11 compliant
  • Full suite of calibration and GPC/SEC calculation types.

Back

How it works

Gel Permeation Chromatography (GPC), also known as Size Exclusion Chromatography (SEC)

This is a chromatographic technique that employs specialized columns to separate natural and synthetic polymers, biopolymers, proteins or nanoparticles on the basis of size.

As the sample is separated and elutes from the column, it can be characterized by a single concentration detector, using ‘Conventional calibration’, to give a relative molecular weight, the addition of viscosity enables the use of ‘Universal calibration’ to give true molecular weight and structural information, and ‘Triple Detection’, which adds light scattering to eliminate column calibration to give absolute molecular weight and distribution.

The TDAmax includes a triple detector and column compartment that are all maintained at a constant temperature to ensure repeatability. The detector cells are optimized in terms of design and volume to minimize any degradation of the separation, to give the maximum resolution and sensitivity.

A single or multiple wavelength UV detector can be added to provide compositional analysis for copolymer analysis or peak identification.

Back

Specification

Complete GPC/SEC system including Conventional, Universal, Light Scattering, Triple, Copolymer, Protein specific, and FIPA calculation modules

Output of Mn, Mw, Mz, Mp, Mw/Mn, IV [η], Rh, Rg, Branching Number, Branching Frequency , Weight Fraction, Concentration, MH-a, MH-k, dn/dc, dA/dc. A2

System
GPCmax:
Pump flow rate:
0.01 to 9.99 mL/min, programmable soft start
Pulsation:
Less than 1%, measured with viscometer
Degasser:
Two channels, < 0.5ppm oxygen at ) 0.5mL/min, eluent
sensor to stop pump when eluent runs out
Dimensions:
55cm x 53cm x 38cm (W x D x H)
Weight:
37kg
Autosampler
Capacity:
120 vials, programmable sequence
Injection volume:
Variable 20 to 150µL
Reproducibility:
Better than 0.5%
Carryover:
Less than 0.1%, depending on wash program
Cooling option:
4°C to 40°C, limited to 60 vials
Heated tray option
Up to 65°C limited to 60 vials heated, 60 vials unheated
Detector:
TDAmax
Temperature range:
Ambient to 80°C, all detector cells and columns
Column capacity:
Up to 5 x 30cm columns
Interface:
6 channel digital to OmniSEC software,
2 analogue inputs RI and UV/LS
Dimensions:
41cm x 54cm x 28cm (W x D x H)
Weight
30Kg
Detector 1:
Light scattering
Measurement principle:
RALS 90° angle, LALS 7° angle
Light source:
3mW laser diode, 670nm, temperature controlled
Cell volume:
18µL
Data rate:
100Hz collection, 5Hz to OmniSEC
Detector 2:
Refractive index
Measurement principle:
Deflection
Light source:
LED
Cell volume:
12µL
Data rate:
100Hz collection, 5Hz to OmniSEC
Detector 3:
Viscometer
Measurement principle:
4 capillary differential Wheatstone bridge configuration
Transducers:
Digital Inert Transducers with over-pressure protection
Cell volume:
18µL
Data rate:
100Hz collection, 5Hz to OmniSEC
Detector 4 (option):
UV, Single wavelength programmable
Wavelength:
190 to 740nm
Light source
Deuterium, Tungsten halogen optional
Cell volume:
10µL
Data rate:
Analog, A-to-D with 5Hz to OmniSEC
Detector 5 (option):
UV-PDA
Wavelength:
190 to 500nm or 710nm on 256 diode array
Light source
Deuterium (190 – 500nm), Tungsten halogen (430 – 710nm)
Cell volume:
10µL
Data rate:
256 channels with 1Hz to OmniSEC
Laser safety:
Class 1
Operating environment:
Temperature:
15°C – 40°C
Humidity:
35% - 80% non-condensing
Software:
OmniSEC, 6 channels at 5Hz, unlimited acquisition time
Minimum computer specification:
100 GB HD, 2GB RAM, 1.8 GHz processor,
Graphics 1024x768, 16-bit color depth
Operating platforms:
Windows XP or higher

Back

Accessories

Malvern - Viscotek accessories include all the components to meet the requirements of your application

Columns Malvern offers a comprehensive range of GPC/SEC columns as part of the Viscotek product portfolio. More information
Standards Polymer standards for multi-detector and column calibration. More information

Back

Support

When you purchase a Malvern product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Some customers just need to ask an occasional question or to download a software upgrade, whilst others require a comprehensive support contract with priority call out and fixed cost of ownership. Whatever your situation Malvern will provide the right support for you.

Help Desk

  • Telephone and email support.
  • Operators who take responsibility for your call and ensure your query is answered.

Training

  • On Site training courses
  • Classroom training
  • e-formation

Resource Centre

  • Application notes
  • Technical notes
  • On demand presentations
  • Live webinars

Téléchargement de logiciel

  • A simple mechanism for receiving updates and new features

Platinum and Gold Service Contracts:

  • Protection from the cost of downtime
  • No time lost in obtaining help when you need it
  • Fixed cost of ownership

Bronze Service Agreements:

  • Protect the value of your investment
  • Reduce the risk of downtime
  • Protect the validity of your data

Back

 
 
Demande de devis Nous contacter
 

Enregistrement gratuit

Accédez aux notes d'applications, webconférences, vidéos, et +

Enregistrez-vous maintenant